{"product_id":"vessel-sealing-system-400w-cautery-machine-electrosurgical-generator-unit","title":"Vessel Sealing System 400W Cautery Machine - Electrosurgical Generator Unit","description":"\u003ch1 data-section-id=\"1yz8jvu\" data-start=\"340\" data-end=\"391\"\u003eProduct Description\u003c\/h1\u003e\n\u003cp data-start=\"393\" data-end=\"622\"\u003eThe \u003cstrong data-start=\"397\" data-end=\"453\"\u003eElectrosurgical Generator with Vessel Sealing System\u003c\/strong\u003e is an advanced surgical unit designed to deliver precise cutting, coagulation, and vessel sealing performance in both minimally invasive and open surgical applications.\u003c\/p\u003e\n\u003cp data-start=\"624\" data-end=\"854\"\u003eAvailable in two models — \u003cstrong data-start=\"650\" data-end=\"676\"\u003eMonoseal Prime Digital\u003c\/strong\u003e and \u003cstrong data-start=\"681\" data-end=\"709\"\u003eExcel Sealer Touchscreen\u003c\/strong\u003e — this system combines controlled energy delivery with tissue compression technology to achieve efficient vessel sealing and surgical precision.\u003c\/p\u003e\n\u003cp data-start=\"856\" data-end=\"1133\"\u003eThe integrated vessel sealing technology enables fusion of vessels up to 7 mm in diameter through a controlled combination of pressure and energy. This system is engineered to provide consistent output, minimal thermal spread, and reliable performance in clinical environments.\u003c\/p\u003e\n\u003chr data-start=\"1135\" data-end=\"1138\"\u003e\n\u003ch1 data-section-id=\"wqb9ds\" data-start=\"1140\" data-end=\"1165\"\u003eAvailable Variations\u003c\/h1\u003e\n\u003ch3 data-section-id=\"ynqkzn\" data-start=\"1167\" data-end=\"1196\"\u003e🔹 Monoseal Prime Digital\u003c\/h3\u003e\n\u003cul data-start=\"1197\" data-end=\"1344\"\u003e\n\u003cli data-section-id=\"1pe2eog\" data-start=\"1197\" data-end=\"1226\"\u003eDigital control interface\u003c\/li\u003e\n\u003cli data-section-id=\"1030eii\" data-start=\"1227\" data-end=\"1249\"\u003eLED display system\u003c\/li\u003e\n\u003cli data-section-id=\"1i4e7np\" data-start=\"1250\" data-end=\"1297\"\u003eReliable performance with standard controls\u003c\/li\u003e\n\u003cli data-section-id=\"76bjnt\" data-start=\"1298\" data-end=\"1344\"\u003eSuitable for general surgical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1346\" data-end=\"1349\"\u003e\n\u003ch3 data-section-id=\"jgcm6o\" data-start=\"1351\" data-end=\"1382\"\u003e🔹 Excel Sealer Touchscreen\u003c\/h3\u003e\n\u003cul data-start=\"1383\" data-end=\"1532\"\u003e\n\u003cli data-section-id=\"eacluu\" data-start=\"1383\" data-end=\"1430\"\u003eAdvanced touchscreen interface (7-inch LCD)\u003c\/li\u003e\n\u003cli data-section-id=\"17pxxsq\" data-start=\"1431\" data-end=\"1461\"\u003e99 programmable user modes\u003c\/li\u003e\n\u003cli data-section-id=\"1950pfb\" data-start=\"1462\" data-end=\"1500\"\u003eEnhanced control and customization\u003c\/li\u003e\n\u003cli data-section-id=\"wz7j6m\" data-start=\"1501\" data-end=\"1532\"\u003eModern user-friendly design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1534\" data-end=\"1537\"\u003e\n\u003ch1 data-section-id=\"135t5zn\" data-start=\"1539\" data-end=\"1555\"\u003eKey Features\u003c\/h1\u003e\n\u003cul data-start=\"1557\" data-end=\"1843\"\u003e\n\u003cli data-section-id=\"1kouveh\" data-start=\"1557\" data-end=\"1608\"\u003eAdvanced vessel sealing technology (up to 7 mm)\u003c\/li\u003e\n\u003cli data-section-id=\"ywph0g\" data-start=\"1609\" data-end=\"1648\"\u003eMonopolar and bipolar functionality\u003c\/li\u003e\n\u003cli data-section-id=\"7yu23p\" data-start=\"1649\" data-end=\"1708\"\u003eMultiple modes: Cut, Blend, Coagulation, Bipolar \u0026amp; Seal\u003c\/li\u003e\n\u003cli data-section-id=\"1uuifjx\" data-start=\"1709\" data-end=\"1755\"\u003eFeedback-controlled energy delivery system\u003c\/li\u003e\n\u003cli data-section-id=\"1j25i8t\" data-start=\"1756\" data-end=\"1788\"\u003eStable high-frequency output\u003c\/li\u003e\n\u003cli data-section-id=\"rg9l5k\" data-start=\"1789\" data-end=\"1843\"\u003eMinimal sticking and optimized sealing performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1845\" data-end=\"1848\"\u003e\n\u003ch1 data-section-id=\"1nnudwu\" data-start=\"1850\" data-end=\"1869\"\u003eOperating Modes\u003c\/h1\u003e\n\u003ch3 data-section-id=\"e0huxz\" data-start=\"1871\" data-end=\"1883\"\u003eCUT MODE\u003c\/h3\u003e\n\u003cul data-start=\"1884\" data-end=\"1930\"\u003e\n\u003cli data-section-id=\"15du448\" data-start=\"1884\" data-end=\"1896\"\u003ePure Cut\u003c\/li\u003e\n\u003cli data-section-id=\"1f3h2fh\" data-start=\"1897\" data-end=\"1918\"\u003eBlend 1 \u0026amp; Blend 2\u003c\/li\u003e\n\u003cli data-section-id=\"10wxlii\" data-start=\"1919\" data-end=\"1930\"\u003eEndocut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lerk7j\" data-start=\"1932\" data-end=\"1945\"\u003eCOAG MODE\u003c\/h3\u003e\n\u003cul data-start=\"1946\" data-end=\"1993\"\u003e\n\u003cli data-section-id=\"1n7dukh\" data-start=\"1946\" data-end=\"1955\"\u003eSpray\u003c\/li\u003e\n\u003cli data-section-id=\"y7av79\" data-start=\"1956\" data-end=\"1965\"\u003eForce\u003c\/li\u003e\n\u003cli data-section-id=\"10bxv8n\" data-start=\"1966\" data-end=\"1979\"\u003eFulgurate\u003c\/li\u003e\n\u003cli data-section-id=\"1a8yvnn\" data-start=\"1980\" data-end=\"1993\"\u003eDesiccate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"vmin7y\" data-start=\"1995\" data-end=\"2011\"\u003eBIPOLAR MODE\u003c\/h3\u003e\n\u003cul data-start=\"2012\" data-end=\"2043\"\u003e\n\u003cli data-section-id=\"10zc3ac\" data-start=\"2012\" data-end=\"2023\"\u003eBi-Coag\u003c\/li\u003e\n\u003cli data-section-id=\"11q0u5o\" data-start=\"2024\" data-end=\"2034\"\u003eBi-Cut\u003c\/li\u003e\n\u003cli data-section-id=\"1wjj207\" data-start=\"2035\" data-end=\"2043\"\u003eAuto\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1tnlvwe\" data-start=\"2045\" data-end=\"2058\"\u003eSEAL MODE\u003c\/h3\u003e\n\u003cul data-start=\"2059\" data-end=\"2112\"\u003e\n\u003cli data-section-id=\"e3ivy6\" data-start=\"2059\" data-end=\"2112\"\u003eVessel sealing with pressure + energy combination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2114\" data-end=\"2117\"\u003e\n\u003ch1 data-section-id=\"nqv9e4\" data-start=\"2119\" data-end=\"2139\"\u003eSalient Features\u003c\/h1\u003e\n\u003cul data-start=\"2141\" data-end=\"2427\"\u003e\n\u003cli data-section-id=\"1yh0eg7\" data-start=\"2141\" data-end=\"2179\"\u003eVessel sealing up to 7 mm diameter\u003c\/li\u003e\n\u003cli data-section-id=\"12asgc5\" data-start=\"2180\" data-end=\"2228\"\u003e99 user-settable program modes (Excel model)\u003c\/li\u003e\n\u003cli data-section-id=\"10ckhjd\" data-start=\"2229\" data-end=\"2283\"\u003eFrequency: 480 kHz (Monopolar) \/ 1 MHz (Seal Mode)\u003c\/li\u003e\n\u003cli data-section-id=\"xjvxnh\" data-start=\"2284\" data-end=\"2336\"\u003eLCD touchscreen (Excel) \/ LED display (Monoseal)\u003c\/li\u003e\n\u003cli data-section-id=\"aje9js\" data-start=\"2337\" data-end=\"2396\"\u003eSeparate monopolar \u0026amp; bipolar \/ seal foot switch support\u003c\/li\u003e\n\u003cli data-section-id=\"803kfz\" data-start=\"2397\" data-end=\"2427\"\u003eCompact and durable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2429\" data-end=\"2432\"\u003e\n\u003ch1 data-section-id=\"1hvglvc\" data-start=\"2434\" data-end=\"2453\"\u003eSafety Features\u003c\/h1\u003e\n\u003cul data-start=\"2455\" data-end=\"2599\"\u003e\n\u003cli data-section-id=\"srk3hy\" data-start=\"2455\" data-end=\"2493\"\u003eProtection class as per EN 60601-1\u003c\/li\u003e\n\u003cli data-section-id=\"1srplgd\" data-start=\"2494\" data-end=\"2532\"\u003eBody and cardiac protection design\u003c\/li\u003e\n\u003cli data-section-id=\"u2i03v\" data-start=\"2533\" data-end=\"2563\"\u003eHF leakage current \u0026lt;150 mA\u003c\/li\u003e\n\u003cli data-section-id=\"14xuwu\" data-start=\"2564\" data-end=\"2599\"\u003ePatient plate monitoring system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2601\" data-end=\"2604\"\u003e\n\u003ch1 data-section-id=\"7gxk5a\" data-start=\"2606\" data-end=\"2634\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2638\" data-end=\"2655\"\u003ePower Output:\u003c\/strong\u003e Up to 400W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2671\" data-end=\"2689\"\u003eInput Voltage:\u003c\/strong\u003e 110V \/ 230V AC (±15%), 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2723\" data-end=\"2737\"\u003eFrequency:\u003c\/strong\u003e 480 kHz \/ 1 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2758\" data-end=\"2769\"\u003eWeight:\u003c\/strong\u003e Approx. 7.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2789\" data-end=\"2804\"\u003eDimensions:\u003c\/strong\u003e 440 × 355 × 155 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2827\" data-end=\"2830\"\u003e\n\u003ch1 data-section-id=\"1y9xy66\" data-start=\"2832\" data-end=\"2856\"\u003eStandard Accessories\u003c\/h1\u003e\n\u003col\u003e\n\u003cli\u003eBipolar forceps with cable\u003c\/li\u003e\n\u003cli\u003eMonopolar \/ bipolar \/ seal foot switch\u003c\/li\u003e\n\u003cli\u003ePatient plate with cable\u003c\/li\u003e\n\u003cli\u003eDisposable hand switch pencil\u003c\/li\u003e\n\u003cli\u003eChuck handle with electrodes\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Vishal Surgical Co","offers":[{"title":"Monoseal Prime Digital","offer_id":56871561167008,"sku":null,"price":1349.0,"currency_code":"USD","in_stock":true},{"title":"Excel-Sealer Touchscreen","offer_id":56871561199776,"sku":null,"price":1749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1035\/0051\/3440\/files\/Monoseal_prime_cautery_Vessel_Sealing_system_device.jpg?v=1774782825","url":"https:\/\/vishalsurgicals.com\/products\/vessel-sealing-system-400w-cautery-machine-electrosurgical-generator-unit","provider":"Vishal Surgical Co","version":"1.0","type":"link"}